Acess ICOM-2S Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Networking Acess ICOM-2S. Acess ICOM-2S User manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - USER MANUAL

ACCES I/O PRODUCTS INC10623 Roselle Street, San Diego, CA 92121TEL (858)550-9559 FAX (858)550-7322MODEL ICOM-2SUSER MANUALFILE: MICOM-2S.Eb

Strona 2

ICOM-2S Manual1-4Manual MICOM-2S.EbFigure 1-1: ICOM-2S Block Diagram(Only one serial channel shown)

Strona 3

2-1Manual MICOM-2S.EbChapter 2: Installation The software provided with this card is contained on either one CD or multiple diskettes and must beins

Strona 4 - Warranty

ICOM-2S Manual2-2Manual MICOM-2S.EbTo copy the files on the master diskette to your hard disk, perform the following steps.1. Place the master diskett

Strona 5 - Table of Contents

2-3Manual MICOM-2S.EbSAMPLESSamples for using ACCES32.DLL are provided in this directory. Using this DLL not only makesthe hardware programming easie

Strona 6 - List of Tables

ICOM-2S Manual2-4Manual MICOM-2S.EbFindbase.exeDOS utility to determine an available base address for ISA bus , non-Plug-n-Play cards. Run thisprogra

Strona 7 - Chapter 1: Introduction

2-5Manual MICOM-2S.EbTo Install the Card1. Turn off computer power.2. Remove the computer cover.3. Remove the blank I/O backplate.4. Install jumpers f

Strona 8 - CE Marking

3-1Manual MICOM-2S.EbFigure 3-1: Simplified SchematicChapter 3: Option SelectionThe following paragraphs describe the functions of the various jumpe

Strona 9 - Specifications

ICOM-2S Manual3-2Manual MICOM-2S.EbSimplex or DuplexThe receiver can be set in either Simplex or Duplex by installing jumpers marked SX or DX. Simple

Strona 10 - Manual MICOM-2S.Eb

3-3Manual MICOM-2S.EbSwitchesS1=COM-A AddressS2=COM-B Address(This illustration has COM A at the COM 3address, and COM B at COM 4 address.)JumpersFDX

Strona 11 - Chapter 2: Installation

4-1Manual MICOM-2S.EbChapter 4: Address SelectionThe ICOM-2S base address can be selected anywhere within an I/O address range 100-3F8 hex,providing

Strona 13

ICOM-2S Manual4-2Manual MICOM-2S.EbI/O bus address switches are marked A3-A9. The following table lists switch label vs. the address linecontrolled a

Strona 14 - Installing the Card

4-3Manual MICOM-2S.EbThe following table lists standard DOS COM port addresses.SerialCOM PortIRQBase HexAddressAddress Switch SettingsA9 A8 A7

Strona 15 - To Install the Card

ICOM-2S Manual4-4Manual MICOM-2S.Eb

Strona 16 - Chapter 3: Option Selection

5-1Manual MICOM-2S.EbChapter 5: ProgrammingSample ProgramsThere are sample programs provided with the ICOM-2S card in C, Pascal, QuickBASIC, and seve

Strona 17 - Interrupts

ICOM-2S Manual5-2Manual MICOM-2S.EbOn the ICOM-2S card, the clock frequency to the UART is 1.843 MHz. Below is a table for thepopular divisor frequen

Strona 18 - Connectors

5-3Manual MICOM-2S.EbThe C command to set the UART for an 8-bit word, no parity, and one stop bit is:outportb(BASEADDR +3, 0x03)The third step of the

Strona 19 - Chapter 4: Address Selection

ICOM-2S Manual5-4Manual MICOM-2S.EbTransmissionRS485 transmission is simple to implement. The AUTO feature automatically enables the transmitterwhen

Strona 20

6-1Manual MICOM-2S.EbChapter 6: Connector Pin AssignmentsThe popular 9-pin D subminiature connector is used for interfacing to communication lines.

Strona 21

A-1Manual MICOM-2S.EbAppendix A: Application ConsiderationsIntroductionWorking with RS422 and RS485 devices is not much different from working with

Strona 22

ICOM-2S ManualA-2Manual MICOM-2S.EbA balanced differential line receiver senses the voltage state of the transmission line across the twosignal input

Strona 23 - Chapter 5: Programming

iiiNoticeThe information in this document is provided for reference only. ACCES does not assume any liability arisingout of the application or use of

Strona 24

A-3Manual MICOM-2S.EbRS485 Data TransmissionThe RS485 Standard allows a balanced transmission line to be shared in a party-line mode. As manyas 32 dr

Strona 25 - Reception

ICOM-2S ManualA-4Manual MICOM-2S.Eb

Strona 26 - Transmission

10623 Roselle Street, San Diego CA 92121Tel. (619)550-9559 FAX (619)550-7322www.accesioproducts.comCustomer CommentsIf you experience any problems w

Strona 27

ivWarrantyPrior to shipment, ACCES equipment is thoroughly inspected and tested to applicable specifications. However,should equipment failure occur,

Strona 28 - Balanced Differential Signals

vTable of ContentsChapter 1: Introduction ... 1-1Multipoint Opto-isolated Communications ...

Strona 29

viList of FiguresFigure 1-1: ICOM-2S Block Diagram ... 1-4Figure 3-1: Simplified Schematic ...

Strona 30 - RS485 Data Transmission

1-1Manual MICOM-2S.EbChapter 1: IntroductionThe card is 10 inches long (264 mm) and should be installed in long slots of IBM PC/XT/AT orcompatible c

Strona 31

ICOM-2S Manual1-2Manual MICOM-2S.EbAuto and Manual Transceiver ControlRS485 communications requires the transmitter driver to be enabled and disabled

Strona 32 - Customer Comments

1-3Manual MICOM-2S.EbSpecificationsCommunications Interface• Serial Ports: Two shielded male D-sub 9-pin IBM AT style connectorscompatible with RS422

Komentarze do niniejszej Instrukcji

Brak uwag